+8613809036020
Home » Resources

Download

Name Size Update Copy Link Download
CEEG Marine Transformer.pdf 1.82MB 2024-09-06 Copy Link
1.82MB
2024-09-06
Copy Link
Prefabricated Substation & Pad-mounted Substation.pdf 5.00MB 2024-06-26 Copy Link
5.00MB
2024-06-26
Copy Link
CEEG Cast Resin Transformer.pdf 2.81MB 2024-06-26 Copy Link
2.81MB
2024-06-26
Copy Link
VPI Transformer-aluk.pdf 9.32MB 2024-06-26 Copy Link
9.32MB
2024-06-26
Copy Link
Mining Flameproof Dry-Type Transformer Substation.pptx 1.86MB 2024-06-26 Copy Link
1.86MB
2024-06-26
Copy Link
Amorphous metal dry type transformer.pdf 5.79MB 2024-06-26 Copy Link
5.79MB
2024-06-26
Copy Link
35Kv Oil Type Transformer-gnnc.pdf 5.57MB 2024-06-26 Copy Link
5.57MB
2024-06-26
Copy Link
220 Kv Power Transformer-jesj.pdf 10.15MB 2024-06-26 Copy Link
10.15MB
2024-06-26
Copy Link
110Kv Power Transformer-piog.pdf 2.66MB 2024-06-26 Copy Link
2.66MB
2024-06-26
Copy Link
Energy Storage Transformer - CEEG.pdf 5.57MB 2024-05-26 Copy Link
5.57MB
2024-05-26
Copy Link

FAQ

  • Q What are the maintenance guidelines for oil-filled transformers?

    A Maintenance notes for both oil-filled transformers and try type transformers include:
    1. Listen for unusual sounds: Regularly check for any abnormal noises during operation.
    2. Ensure the machine is off: Prior to maintenance, ensure the transformer is powered down and isolated from the electrical supply.
    3. Perform a visual inspection: Examine the transformer for signs of leaks, corrosion, or damage.
    4. Clean the transformer: Keep the transformer exterior and surrounding area clean to prevent dust buildup.
    5. Tighten loose bolts and hardware: Periodically check and tighten any loose bolts or hardware to maintain structural integrity.
    6. Run tests: Conduct routine tests to ensure the transformer is functioning correctly and within specified parameters.
     
    The following maintenance steps are required specifically for oil transformations:
    l Check oil levels: Regularly monitor oil levels and ensure they are within the recommended range.
    l Change filters: Replace oil filters as needed to maintain oil cleanliness and system efficiency.

  • Q What causes a dry type transformer to overheat?

    A Several factors can cause overheating, including improper load rating selection, inadequate airflow, poor insulation, and low-quality windings. To prevent this, it's crucial to select a transformer with a rating suitable for the intended application, install a dry-type unit in a location with sufficient airflow and ventilation, and choose a unit with excellent insulation and high-quality windings.
  • Q Why my dry type transformer makes loud humming noises?

    A If you notice an unusual humming noise from your transformer, it could be due to overloading, aging, loose components, or poor design. To minimize noise and ensure long-lasting operation, it's crucial to select a dry-type transformer with high-quality insulation, superior coiling, excellent construction, and overall good quality.
  • Q Why you need to contact us to customize dry-type transformers used in altitudes above 1000 meters?

    A Dry-type transformers operating above 1000 meters need to be derated due to the diminished cooling capacity of the less dense air. The transformer's capacity should be reduced by 0.3% for every 100 meters above 1000 meters.
  • Q Can 60Hz transformers be used at 50Hz?

    A Transformers with a capacity of 1KVA or more, designed for 60Hz, should not be operated at 50Hz because they will experience increased losses and heat rise. However, a transformer rated for 50Hz can be used on a 60Hz service.
  • Q How to select the right transformers?

    A 1. Transformer Capacity
    Determine the maximum power the transformer needs to provide. Incorrect capacity can lead to overloading or inefficiency. Calculate the required capacity based on your load profile and energy demands.
     
    2. Transformer Size
    l For a single-phase transformer, use the formula:
    V×I/1000. For example, 150×50/1000=7.5kVA
    l For a three-phase transformer, use the formula: V×I×1.732/1000.
    Contact us to ensure the transformer fits your needs before placing the order.
     
    3. Voltage Levels
    Ensure the voltage levels are compatible with your existing energy distribution system.
     
    4. Frequency
    Match the transformer's rated frequency with your system frequency.
     
    5. Location
    Some models are purpose-built to handle moisture and humidity, some are flame and explosion proof, while others boast extra protection against the corrosion near the ocean.
    Indoor transformers must fit in your space. Adequate space for installation is necessary to avoid issues like receiving equipment that doesn’t fit through the door.
     
    6. Compliance and Regulatory Standards
    Ensure the transformer meets industry and national compliance for reliability, safety, and durability.
     
    7. Energy Efficiency
    Opt for transformers with low energy losses and high-efficiency classes to manage operating costs effectively and reduce environmental impact.
     
  • Q Why is transformer selection important?

    A Efficient and cost-effective transformer selection is crucial for industrial, commercial, residence, and utility operations. Downtime can be costly, so a reliable energy source is essential. While cheaper transformers may seem economical initially, investing in a high-quality, reliable transformer saves money over time by ensuring consistent performance and reducing losses.
  • Q What are your accepted terms of international trade?

    A FOB, CIF, FCA

Industrial Knowledge

  • The Low Flammability Advantage of Cast Resin Transformers
    Introduction In the world of electrical engineering, safety and efficiency are paramount. One of the standout innovations in this field is the Cast Resin Transformer. Known for its low flammability and robust performance, this type of transformer is becoming increasingly popular. But what exactly ma
    Read More
  • Maximizing Safety and Reliability with Cast Resin Transformers in Industrial Applications
    Introduction In the dynamic world of industrial applications, ensuring safety and reliability is paramount. One of the key components that play a crucial role in this regard is the Cast Resin Transformer. These transformers are engineered to offer exceptional performance, making them an indispensabl
    Read More
  • The Dual Advantages of High Efficiency And Excellent Insulation in 110kV Oil-immersed Power Transformers
    Introduction In the realm of electrical engineering, 110kV Oil-immersed Power Transformers stand as a testament to technological advancement. These transformers are not just another piece of equipment; they are the backbone of efficient power distribution. This article delves into the dual advantage
    Read More
  • The Corrosion Resistance of Low and Medium Voltage Marine Transformers
    Introduction In the world of marine engineering, the durability and efficiency of equipment are paramount. Among the essential components are Low and Medium Voltage Marine Transformers, which play a critical role in ensuring the seamless operation of marine vessels. One of the most significant chal
    Read More
  • How Integrated Storage Units Improve Grid Reliability
    Introduction In today's rapidly evolving energy landscape, the importance of grid reliability cannot be overstated. As we transition towards more sustainable energy sources, the role of advanced technologies like the Integrated Energy Storage Booster and Converter Unit becomes increasingly vital. Th
    Read More
  • Total 2 pages  Go to Page
  • Go

Telephone

+86-17826020132
FOLLOW US

PRODUCTS

QUICK LINKS

CONTACT US
​Copyright © 2024 CEEG Nanjing Transmission & Distribution Equipment Co., Ltd. | Sitemap | Privacy Policy